Hospital ICU Anesthesia Machine

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2020-12-13 02:44

  • Browse the number:

    491

Send an inquiries
+
Full Medical Co., Ltd
Contactaixin:

hffumai(Mr.)  

Email:

telephone:

phone:

Arrea:

Beijing

Address:

9#, Wanzhen Xiaoyao Garden,Ma Anshan Road, Baohe Zone, Hefei City, Anhui Province, China

Website:

http://www.fullmedi.com/ http://hffumai.5564310.com/

+

Products Description

* The Ventilator adopts microcomputer control with high-definition 5.7” LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.

* The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.

* Reliable pneumatic transmission system.

* Economic and proper configuration of technologies, optional as required by the Customer.

* Modularized design and upgrading. Upgrading is available as required by the Customer.


Technical Parameters

Part of Hospital ICU Anesthesia Machine

* Main body High-strength engineering plastic rack, light, beautiful and corrosion resistant
* Scope of application adult, child
* Gas source O2: 0.27~0.55MPa; N2O: 0.27~0.55MPa
* Flow meter O2: 0.1~10L/min; N2O: 0.1~10L/min
* O2, N2O linkage and N2O Stopper

When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off.

* Flow rate of rapid oxygen supply 25~75L/min
* Low oxygen pressure alarm There will be sound alarm when the oxygen pressure < 0.2MPa
* Vaporizer It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
* Respiratory circuit

working mode: all-close, semi-close, semi-open

releasing pressure: 0.5~7 kPa

* Respiratory bellows

bellows for adults, bellows for children

tidal volume range:0~1,500 ml


Part of Ventilator

* Display mode High-definition 5.7” LCD screen display
* Ventilation mode IPPV,SIPPV,SIMV,PEE,MANUAL,SIGH
* Ventilation parameters Tidal volume 50~1500ml
Rate 2~99bmp
SIMV rate 2~20bpm
I:E 2:1~1:8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range 1.0~6.0 kPa
SIGH 1.5 times the inspiratory time

* Parameters for ventilation

monitoring

tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
* Monitoring of oxygen concentration (21%~100%)
* Security Alarm System Oxygen Concentration alarm

upper limit setting range (50%~100%)

low limit setting range (15%~50%)

Airway pressure alarm

upper limit setting range 1.0~6.0 kPa

low limit setting range 0.4~2.0 kPa

Per-minute ventilation volume alarm upper limit setting range

upper limit setting range 3.0~30L/min

low limit setting range 1.0~10L/min

Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is no tidal volume input for 15 seconds
Power alarm
* Power AC 220V±10%; 50Hz±1Hz; (UPS, Storage battery)
* Items within brackets are optional.