JLSZW6-12 three-phase outdoor epoxy resin casting combined transformer (also called high voltage outdoor powers
metering cabinet), is made up of two current transformers and two potential transformers
Widely used outdoor for measuring current and electric energy in the electric system with the frequency 50Hz or 60 Hz and highest voltage for equipment 12kV
The product has the feature of high precision, low temperature rise, fireproofing, explosion protection, electricity theft prevention and good dynamic hot stability and more
The product has the feature of high precision, low temperature rise, fireproofing, explosion protection, electricity theft prevention and good dynamic hot stability and more
Main Technical Parameter:
Voltage transformer
Current transformer
Remarks:Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Outline Drawing
JLSZW6-12 three-phase outdoor epoxy resin casting combined transformer (also called high voltage outdoor powers
metering cabinet), is made up of two current transformers and two potential transformers
Widely used outdoor for measuring current and electric energy in the electric system with the frequency 50Hz or 60 Hz and highest voltage for equipment 12kV
The product has the feature of high precision, low temperature rise, fireproofing, explosion protection, electricity theft prevention and good dynamic hot stability and more
The product has the feature of high precision, low temperature rise, fireproofing, explosion protection, electricity theft prevention and good dynamic hot stability and more
Main Technical Parameter:
Voltage transformer
Rated voltage ratio (kV) |
Accuracy class | Rated output (VA) |
Max output (VA) |
Rated insulation level (kV) |
11/0.11 11/0.11 |
0.2 or 0.5 | 15 or 25 | 300 | 12/28/75kV |
Current transformer
Rated voltage ratio (kV) |
Accuracy class | Rated output (VA) |
Rated short-time themal current (Ith) | Rated dynamic current | Rated insulation level (kV) |
5-300/5 | 0.2 or 0.2S | 7.5 or 15 | 15 or 25 | 2.5 Ith | 12/28/75kV |
Remarks:Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.